MAX-HT™ Low Voltage Crusher Duty – Design A
Totally Enclosed Fan Cooled, [CDP]
Categories: Stock Motors, Three Phase TEFC Motors
HP | 200 HP through 500 HP |
Speed | 1800, 1200, 900 RPM |
Voltage | 460V |
Frequency | 60 Hz. |
Features
- Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
- CSA Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3 Minimum
- CSA Certified for Class II, Div. 2, Groups F & G - Temp Code T3 Minimum (Frame 444T and above)
- Class F Insulation
- Class B Temperature Rise
- NEMA Design A Torques; Equal or Greater Than 200% Starting Torque / 250% Breakdown Torque
- Cast Iron Frame, End Brackets; Pressed Steel Plate Main Conduit Box and Fan Cover
- Cast Iron Main Conduit Box on 505UZ Frame
- Grounding Terminal Inside Main Conduit Box with additional Foot Grounding Provision
- Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
- Designed for 40˚C Ambient Temperature
- Designed for 3300 ft. Elevation
- Bi-Directional Rotation
- High Strength 4140 AISI Steel Shaft
- Aluminum Die Cast Squirrel Cage Rotor Construction
- Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
- Paint Color: Dark Gray - Munsell 7.5 BG 3.5/0.5
- High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM
- Automatic Grease Discharge Fittings
- Labyrinth Type Metal Flinger on Both Ends
- Cast Iron Inner and Outer Bearing Caps
- Stainless Steel Nameplate
- New Dual Column Design Nameplate as Standard (60/50 Hz)
- Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
- Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque (350 HP and Larger are 3:1 Constant Torque)
- 6 Leads
- Standard With Thermistors (PTC 140˚C) 1 per Phase
- Locknut and Washer on NDE for Vertical Shaft Down Applications
- Drain Holes / Plugs on Both End Brackets for Vertical Applications
- Threaded One Way Breather Drains for Horizontal Mount Applications
Product Categories
Resources & Downloads
More Stock Motors
-
80MAX-HT™ Low Voltage Crusher Duty – Design A
Totally Enclosed Fan Cooled, [NP], [NP_C], [NPV_C]
-
100MAX-HT™ Low Voltage Crusher Duty – Design A
Totally Enclosed Fan Cooled, [XP], [XP_C], [XPV_C]
-
41MAX-HT™ Low Voltage Crusher Duty – Design A
Totally Enclosed Fan Cooled, [CP]
-
53MAX-HT™ Low Voltage Crusher Duty – Design A
Totally Enclosed Fan Cooled, [EP], [E], [E]_C], [EPV_C]
-
31MAX-HT™ Low Voltage Crusher Duty – Design A
Open Drip Proof
-
75MAX-HT™ Low Voltage Crusher Duty – Design A
Totally Enclosed Fan Cooled, [KD]
-
86MAX-HT™ Low Voltage Crusher Duty – Design A
Totally Enclosed Fan Cooled, [NV_C]
-
92MAX-HT™ Low Voltage Crusher Duty – Design A
Totally Enclosed Fan Cooled, [GH], [GP], [GH_C], [GHV_C], [GP_C], [GPV_C]